Red plague of silver coated copper wire cable and harness assemblies.
Silver plated copper wire red plague.
Several investigative activities were undertaken by esa in the mid seventies.
Most importantly wire manufacturers should avoid mechanical abrasion of the silver plated conductor in the stranding and braiding process.
The environmental test system artificially promotes red plague corrosion under controlled laboratory conditions as a result of galvanic corrosion of the copper conductor core.
These included laboratory evaluations a european red plague survey and eventually the.
Red plague forms when the silver plating is damaged exposing the copper wire to moisture or high temperatures.
Both corrosion products are generated by the electrochemical reaction induced when a galvanic cell is formed between the copper core and the silver plating.
Nor do i have any opinion on those particular cables.
Some wire cable manufacturers have found a way to minimize the likelihood of red plague.
Prescribes the minimum requirements for the control of cuprous cupric oxide corrosion a k a.
I ve never used silver plated wire for speaker cable personally so i have no opinion on sonic differences if there are any.
There is an industry accepted method for measuring key factors in a wire s red plague susceptibility.
0 003 had a significant amount of red plague and that no malfunctions could be attributed to this phenomenon.
Most often it is seen as spots of brown or red on the silver plating.
109 ft of silver plated copper wire only 105 ft i e.
The term red plague was coined to describe the red cu 2 o and eventually the black cuo troublesome corrosion by products observed in silver plated copper conductors.
Red plague is an accelerated corrosion of copper when plated with silver after storage or use in high humidity environment cuprous oxide forms on the surface of the parts the corrosion is identifiable by presence of patches of brown red powder deposit on the exposed copper.
Silver however can tarnish and silver plated wire is susceptible to red plague if moisture gets between the wire and the insulation.
Wire manufacturers must keep equipment in a clean environment.
The appearance of red coloured corrosion products on silver plated copper wire has led to the use of the term red plague to describe the problem.
Red plague is a term that refers to a specific type of silver plated copper corrosion.
Red plague control plan.
Silver plated raw material must be kept in a low humidity environment below 50 percent relative humidity.
Targeted for applications where exposure to assembly processes environmental conditions and contamination may promote the development of cuprous cupric oxide corrosion a k a.
Red plague or cupros oxide is the name given to the corrosion effect found in silver plated copper wire.